4 Description of function
22 V-700/710 Operation Manual, Version E
4.3.1 Front view EasyVac
1
2
3
4
5
6
Fig. 4.8: Front view EasyVac
a Detection start of distillation b Detection end of distillation
Fig. 4.9: Pressure course in EasyVac mode
a Start
By pressing the START button the pump starts evacuating the system until the solvent in the evapo-
rating flask starts boiling. Then the pressure is adapted according to the vapor pressure curve and the
end point of the distillation is determined. Based on sophisticated algorithms the process is executed
in a robust, gentle way.
Continuous
By pressing the START button for more than 2 seconds, the pump enters the Continuous mode,
where it operates constantly.
b Stop
When pressing the STOP button the pump stops and the system is aerated by means of the valve at
the controller.